Monday, November 25, 2024

Telephone Receiver

This simple telephone receiver without a dialing section can be connected in parallel to a telephone line. It can be easily assembled on a small veroboard or a PCB. A geometry box made in the shape of a telephone receiver will be an excellent cabinet for it. No external power supply is needed, which makes the circuit handy.

Telephone Receiver Circuit

Telephone Receiver Circuit
Telephone Receiver Circuit

The ringer section comprises R1, C1, and a buzzer. If your telephone has a loud ringer, this circuit can be avoided. A bridge rectifier consisting of diodes D1 through D4 protects the circuit from any polarity change in the telephone line. PNP transistor MPS-A92 (T1) is the main interface transistor. The output of T1 is regulated by zener diode ZD and capacitor C2 to get 6.8V for powering the amplifier section. This power is also used to bias the transmitter section.

The transmitter section comprises transistor BC548 (T2) together with a few discrete components and a condenser microphone. The transmit signal is fed to the base of interface transistor T1. The voice input for the amplifier comes directly from the positive end of the bridge rectifier.

- Advertisement -

The amplifier section is built around high-performance, low-wattage power amplifier IC LM386. This circuit is designed as a high-gain amplifier. A small 8-ohm speaker is good enough for the output.

After all soldering is done, adjust presets VR1 and VR2 to their middle position and connect the circuit to the telephone line in parallel. Adjust VR1 and VR2 for optimum reception as well as transmission.

- Advertisement -

The article was first published in January 1997 and has recently been updated.

12 COMMENTS

  1. Hello, my name is Lucas, I am from Brazil.

    First of all, thanks for providing this circuit and congratulations for this website.

    I have a doubt: is it possible to change the switch for a flip flop T circuit in a way that I could a tactile switch?

    Thanks!

  2. Dear Kas,
    Thank you for posting your query in electronicsforu.com
    Follow these steps to rectify the problems.
    1. Check the connections properly.
    2. After connecting the telephone line keep the changeover switch S towards bridge side
    3. Check the voltage across cathode of ZD,it should be 6.8V
    4. Replace the LM386.
    5. Keep VR1 and VR1 in middle.
    6. Once this is done, hope circuit should work

    If you have any further queries, feel free to contact us. We will be happy to help you.

    Thank you.